Input of Analytical Data
You may only input the analysis data on the “individual water” sheet. If you wish, the parameters can be entered in either [mg/l] or [mmol/l]. Conversions between the units are executed by a single button click.
WinWASI 5.0 calculates the with all combinations of pairs of pH, SK, BK and DIC. It should be noted here, that only two of the four parameters pH, SK, BK and DIC must be known for the calculation. If there are more than two parameters, WinWASI 5.0 displays all calculation results. As such the quality of the analytical data can easily be verified by comparing the different results.
Results of calculation
WinWASI 5.0 displays the following results of calculation:
- pHtb
- m- and p-value
- Total Hardness
- Carbonate Hardness
- pHLtb (Langelier and Strohecker)
- pHCtb (Calcite Saturation)
- pH (Calcite Dissolution Capacity 5 mg/l)
- Delta-pH
- SI (Calcite)
- Dtb (Calcite Saturation)
- D (Calcite Saturation at 60°C)
- D (Calcite Saturation at 90°C)
- Bound Carbon Dioxide
- Aggressive Carbon Dioxide
- Ionic Strength
- Charge Balance
- Total Dissolved Solids
- Corrosion Quotients S1, S2, S3 according EN 12502
- Cation Quotient
- Saturation Indices for BaSO4, SrSO4, CaSO4, CaF2, Mg(OH)2, SiO2